4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
FE-32 is used to select the elevator functions. Each bit of the parameter denes a function, as described in the
following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
The functions dened by the binary bits of FE-32 are described in the following table.
Bit Function Description Default
Bit0
to
Bit1
Reserved - 0
Bit2 Re-leveling function
The elevator performs re-leveling at a low speed with door open.
An external shorting door lock circuit contactor needs to be used
together.
0
Bit3 Door pre-open function
During normal stop, when the elevator speed is smaller than a
certain value and the door zone signal is active, the system shorts
the door lock by means of the shorting door lock circuit contactor
and outputs the door open signal, implementing door pre-open.
This improves the elevator use efciency.
0
Bit4 Stuck hall call cancellation
The system automatically identies the state of the hall call
buttons. If the state is abnormal, the system cancels the stuck hall
call.
0
Bit5
Night security oor
function
From 10:00 p.m to 6:00 a.m., the elevator runs to the security oor
rst every time, stops and opens the door, and then runs to the
destination oor.
0
Bit6
Down collective selective
peak service
The peak service at down collective selective is used. 0
Bit7
Parallel/Group control
peak service
The peak service is used. 0
Bit8
Time-based service oor
function
For details, see the description of related parameters in group F6. 0
Bit9 VIP function The VIP function is used. 0
Bit10 Reserved - 0
Bit11 Car call deletion
A call can be deleted by pressing the button twice consecutively.
1
Bit12 Hall call deletion 0
FE-33
Elevator function
selection
Bit1: Door open holding at open
limit
Bit2: Door close command not
output upon door close limit
Bit4: Auto reset for RUN and brake
contactor stuck
Bit5: Slow-down switch stuck
detection
Bit7: Forced door close
Bit15: Opposite door independent
control