- 122 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
FE-33 is used to select the elevator functions. Each bit of the parameter deīænes a function, as described in the
following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
The functions deīæned by the binary bits of FE-33 are described in the following table.
Bit Function Description Default
Bit1
Door open holding at
open limit
The system still outputs the door open command upon door open
limit.
0
Bit2
Door close command not
output upon door close
limit
The system stops outputting the door close command upon door
close limit.
1
Bit4
Auto reset for RUN and
brake contactor stuck
If the feedback of the RUN and brake contactors is abnormal,
faults Err36 and Err37 are reported, and you need to manually
reset the system.
With this function, the system resets automatically after the fault
symptom disappears. A maximum of three auto reset times are
supported.
0
Bit5
Slow-down switch stuck
detection
The system detects the state of slow-down switches. Once
detecting that a slow-down switch is stuck, the system instructs the
elevator to slow down immediately and reports a corresponding
fault.
1
Bit7 Forced door close
If the door still does not close within the time set in Fb-17 in
automatic state, the system outputs the forced door close signal;
at this moment, the light curtain becomes invalid and the buzzer
tweets.
0
Bit15
Opposite door
independent control
- 0
Group FF: Factory parameters
Group FJ: Factory parameters
Group FP: User parameters
FP-00 User password
0: No password
01 to 65535
0 -
ā
FP-01 Parameter update
0: No operation
1: Restore default setting (except
group F1)
2: Clear fault records
3: Clear shaft parameters
0 -
ā
FP-02
User-deīæned parameter
display
0: Invalid
1: Valid
0 -
ā
FP-05 Contract No. 2 0 to 65535 0 -
ā
FP-06 Contract No. 1 0 to 65535 5555 -
ā
Group Fr: Leveling adjustment parameters
Fr-00
Leveling adjustment
function
0: Disabled
1: Enabled
0 -
ā
Fr-01
Leveling adjustment
record 1
0 to 60060 30030 mm
ā
~ ~ 0 to 60060 30030 mm
ā