Example:
If īoors 2, 8, 9, and 12 of a 16-īoor elevator need to be forbidden, and all other īoors are in service, we need to
set Bit1, Bit7, Bit8, and Bit11 corresponding to īoors 2, 8, 9, and 12 to 0, and set the other bits to 1, as shown in
the following īægure.
1
0
4
8
16
32
64
0
0
512
1024
0
4096
8192
16384
32768
Bit2 = 1
Bit1 = 0
Bit3 = 1
Bit4 = 1
Bit5 = 1
Bit6 = 1
Bit7 = 0
Bit8 = 0
Bit9 = 1
Bit10 = 1
Bit11 = 0
Bit12 = 1
Bit13 = 1
Bit14 = 1
Bit15 = 1
Bit0Bit11
Bit1Bit2Bit3Bit4
Bit5Bit6Bit7
Bit8Bit9Bit10Bit12Bit13
Bit14
Bit15
1612
248
1632
64128256
10242048
4096
8192
Bit Addressing
Binary Addressing
16384
32768
Floor 1
Floor 2
Floor 3
Floor 4
Floor 5
Floor 6
Floor 7
Floor 8
Floor 9
Floor 10
Floor 11
Floor 12
Floor 13
Floor 14
Floor 15
Floor 16
Bit0 = 1
Forbidden
Forbidden
Forbidden
Forbidden
Convert the binary value to decimal:
1 + 4 + 8 + 16 + 32 + 64 + 512 + 1024 + 4096 + 8192 + 16384 + 32768 = 63101
Then, enter ā63101ā for F6-05 on the operation panel.
F6-07
Number of elevators in
parallel/group mode
1 to 8 1 -
ā
F6-08 Elevator No. 1 to 8 1 -
ā
F6-09 Elevator program control
Bit0: Dispersed waiting
Bit2: Reserved
Bit3: Parallel/Group control
implemented at CAN2
Bit4: Group control in compatibility
with NICE3000
Bit6: Clear īoor number and
display direction in advance
Bit8: Unidirectional hall call (single
hall call button)
Bit 9: Not detecting analog wire
breaking
Bit10: Cancellation of ERR30
judgment at re-leveling
Bit14: Time interval detection
of safety circuit 2 and door lock
circuit 2 (1.5s)
0 -
ā