- 94 -
4 Parameter Description
4
Parameter
No.
Parameter Name Setting Range Default Unit
Property
F6-09 is used to select the elevator functions. Each bit of the parameter denes a function, as described in the
following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled. For
details on how to view and set this parameter, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-09 are described in the following table.
Bit Function Description Default
Bit0 Dispersed waiting
In single elevator or parallel/group mode, if this function is
enabled, an idle elevator will not return to the base oor.
In group mode, this function is used together with the group control
board to implement dispersed waiting.
0
Bit3
Parallel/Group control
implemented at CAN2
This function is enabled when the parallel/group mode is
implemented at CAN2 on the MCB.
0
Bit4
Group control in
compatibility with
NICE3000
This function is used when the NICE3000 is involved in the group
control system. The setting of this bit must be the same as that for
all the other elevators in the group.
0
Bit6
Clear oor number
and display direction in
advance
The displayed oor number is cleared before the elevator reaches
the destination oor.
If the elevator needs to change the direction, the changed direction
is displayed in advance.
0
Bit8 Single hall call button It is applied to applications where there is only one hall call button. 0
Bit9
Not detecting analog wire
breaking
The system does not detect analog wire breaking during normal
running.
0
Bit10
Err30 judgment at re-
leveling cancellation
It indicates Err30 judgment when re-leveling is cancelled. 0
Bit14
Time interval detection of
safety circuit 2 and door
lock circuit 2
If the states of safety circuits 1 and 2 or the states of door lock
circuits 1 and 2 are inconsistent, the system will prohibit running.
After the states restore normal, the system is powered on again
and starts running.
0
F6-10
Leveling sensor lter
time
10 to 50 14 ms
ā˜…