Routine Maintenance
4
1 Routine Maintenance
1.1 Routine Maintenance
Standard operating conditions:
Average annual ambient temperature: 30℃ Average load rate: 80% Daily operating
time: 20 h
1.1.1 Routine Checklist
Check the following items during routine inspection.
Table 1–1 Routine checklist
No.
Routine Checklist Checked
1
The ambient temperature and humidity are normal.
There is no dust or unwanted objects in the servo drive.
2 There is no abnormal vibration or noise.
3
The voltage of the power supply is normal.
4
There is no strange smell.
5
There are no fibers adhered to the air inlet.
6
There is no intrusion of unwanted object on the load
end.
1.1.2 Routine Cleaning List
Check the following items during routine cleaning.
Table 1–2 Routine cleaning list
No.
Routine Cleaning List
Checked
1
Clean the dust on the equipment surface, especially
the metallic dust.
2
Keep the front end of the servo drive and the
connectors clean.
Note
Cut off the power supply before cleaning. Clean the equipment with an air gun or a
piece of dry cloth.
Do not use the gasoline, diluent, alcohol, acidic or alkaline detergent during
cleaning to prevent enclosure discoloration or damage.