13
3.6 Print
If the weighing is stable, after connect with printer, press” PRINT”
can print the weight. Note: at tare mode, print with tare. if negative
weight,, can not print. Set C30 for time format.
3.7 Hold
There are two different hold function. Peak hold function and data hold
function. And the setting is different accordingly.
C11=3 Automatic hold function C11=0 close hold function.
3.8 COUNT
1.At weighing mode, load the weights on the platform scales, Press”
Count” the indicator show” PCS 0” press” Zero” key input the quantity,
press” Print” to confirm it
2 . Load the goods on the platform scales, then the indicator will show
the quantity.
3. Press” Count” back to weighing mode.
4. If you want to weigh different goods, at weighing mode, put the
sample on the platform scales, press” Count” the indicator show”0”
Press “ Count” hold it and then press “ ON/OFF” the indicator show”
PCS 0”, press “Zero” input the sample quantity, press “ Print” to
confirm it. Then repeat the step 2 and 3.