EasyManua.ls Logo

Inscale LP-7510 - Application Function Parameters

Inscale LP-7510
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
4.3 Application function parameters setting chart
Function
Setting
Item
parameters setting and instruction
warning
tone
C08
warning
tone
Options: 0 = close warning tone
1 = open warning tone
Automatic
power off
C09
Automatic
power off
option0=close auto power off
10= power off automatically if no
change within 10 minute.
30= power off automatically if no
change within 30 minute.
60= power off automatically if no
change within 60 minute.
Power saving
setting
C10
Power saving
setting
LED Version:
option0= close power saving setting
3= close display if no change within 3min.
5= close display if no change within 5 min.
LCD Version:
0=Close he backlight
1= backlight when the weight change or
press the keyboard
2=constant backlight
Hold
function
C11
Hold mode
option0=close hold function
1=Peak hold /2=Data Hold
Instruction:
Peak-hold: it shows the maximum. data,
mainly application for materials testing,
such as tension and pulling force.
Date-hold: it shows current weight value.
Mainly application for animal weighing.
Kg/lb
conversion
C12
Kg/lb
conversion
C12=0 stop kg/lb conversion
C12=1 kg/lb conversion is ok