Step 6: Option C - Adapting blower for recirculation
1 Remove and save the five screws that hold the blower unit in the microwave.
2 Carefully pull out the blower unit. The wires will extend far enough to let you adjust the blower unit. Do not
disconnect the wires.
3 Turn the blower unit 90° so that the fan blade openings are facing the front of the microwave.
Warning
Do not pull or stretch the blower unit wiring. Make sure that the wires are not
pinched.
Remove blower plate and
adapter screws and save
Remove blower motor screws
and save
Back of microwave
Blower unit
Remove blower plate and
adapter screw and save