6 Restart Windows.
Setting Full Duplex in Other Operating Systems
See the OTHER.TXT readme file in the \OTHER directory on the PRO/100+
Client adapter disk. Open the file with any text editor.
Troubleshooting and FAQs
If the Adapter Can’t Connect to the Network
Make sure the cable is installed properly.
The network cable must be securely attached at both RJ-45 connections (adapter
and hub). The maximum allowable distance from adapter to hub is 100 meters.
If the cable is attached and the distance is within acceptable limits but the
problem persists, try a different cable.
If you’re directly connecting two computers without a hub or switch, use a
crossover cable.
Check the LED lights on the adapter.
The adapter has two diagnostic LEDs, one on each side of the cable connector.
These lights help indicate if there’s a problem with the connector, cable, or
switch/hub.
LED Function Indicators
LED Indication Meaning
ACT/LNK On The adapter and switch are receiving
power; the cable connection between the
switch and adapter is good.
Off The adapter is not sending or receiving
network data. The adapter and switch are
not receiving power; the cable connection
between the switch and adapter is faulty;
or you have a driver configuration prob-
lem.
Flashing The adapter is sending or receiving net-
work data. The frequency of the flashes
varies with the amount of network traffic.
100 On Operating at 100 Mbps.
Off Operating at 10 Mbps.
P100se~2.fm Page 14 Tuesday, January 5, 1999 10:04 AM