Antenna / Satellite Signal Level
System fails to power up
Symptons Descriptions / Remedial Actions
Low Signal Strength
• Check any obstruction such as the hull or monkey bridge of the vessel
that may block the ADU’s line of sight. 
• Check any interference signal from other electronics devices that are
close to the ADU
• Check to ensure that the antenna cable is properly secured.
• Depending on the antenna’s location on the vessel, the vessel’s route 
may cause the ADU’s line of sight to be blocked by any structure of
the vessel, depending on the elevation of the satellite.
Symptons Descriptions / Remedial Actions
No light appear on
BDU LED.
• Ensure the power switch on the front panel is at  “On”  position.
• To reset the circuit breaker on the front panel by depressing the lever
of the circuit breaker inward fully and release.
• Check to ensure that the input DC power will have at least +24VDC,
10A or +12VDC, 20A.