Titan Instructions for Use - EN Page 8
9. Do not disassemble or modify the product as this may impact on the safety and/or performance of
the device.
NOTICE
1. DO NOT connect the Titan hardware to the computer before the software has been installed!
2. Storage in temperatures below 0°C /32°F and above 50°C /122°F may cause permanent damage to
the instrument and its accessories.
3. Do not place the instrument next to a heat source of any kind, and allow sufficient space around the
instrument to ensure proper ventilation.
4. Although the instrument fulfils the relevant EMC requirements, precautions should be taken to avoid
unnecessary exposure to electromagnetic fields, e.g. from mobile phones etc. If the device is used
adjacent to other equipment, caution must be taken to observe that no mutual disturbance appears.
5. The temperature of the battery pack in the Able AP1300 thermal printer will rise if it is powered
through both the printer’s power supply and through the RJ12 cable to the cradle. Use either one or
the other power connections, but never both, as this may severely reduce the lifetime of the battery.
6 Great care should be exercised when handling transducers, as rough handling, for example dropping
onto a hard surface may break or damage the parts.
7. The connectors marked with the symbol shown below should not be touched without taking
necessary ESD (electrostatic discharge) precautions.
The precautionary symbol:
8. The best way to protect the Titan from ESD is to avoid the build-up of electrostatic charges through
the use of conductive footwear and floor coverings. Humidification of the air is also an effective
preventive means. Failing to comply with these measures can cause the build-up of voltage levels of
several thousand volts. If the Titan is subjected to such an ESD pulse, it may be necessary to
remove the battery for a few seconds and then restart the instrument.
Within the European Union it is illegal to dispose of electrical and electronic waste as
unsorted municipal waste. Electrical and electronic waste may contain hazardous
substances and therefore have to be disposed of separately. Such products will be marked
with the crossed-out wheelie-bin image shown to the left. User cooperation is important in
order to ensure a high level of reuse and recycling of electrical and electronic waste. Failure
to recycle such waste products in an appropriate way may endanger the environment and
consequently the health of human beings.
Outside the European Union, local regulations should be followed when disposing of the product after its
useful life.

Table of Contents

Other manuals for Interacoustics Titan

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interacoustics Titan and is the answer not in the manual?

Interacoustics Titan Specifications

General IconGeneral
CategoryMeasuring Instruments
DisplayColor touch screen
OAEYes
DiagnosticYes
Battery LifeUp to 8 hours
Frequency Range226 Hz, 678 Hz, 800 Hz, 1000 Hz
Probe Tone Level85 dB SPL
Test TypesTympanometry, Reflex
ConnectivityUSB
Power SupplyRechargeable Battery