Questions and Answers

  • J
    Jose WolfAug 12, 2025
    What to do if Interface Security Sensors show wrong torque indication?
    • M
      Michelle RossAug 12, 2025
      If your Interface Security Sensors are showing the wrong torque indication, there could be several reasons: * The shaft may be overloaded, in which case you should send it to the manufacturer. * The calibration might not be correct, so try re-calibrating the sensor. * There could be a sensor defect, requiring repair by the manufacturer. * A torque shunt might be present; eliminate the shunt to resolve the issue.
  • L
    Lisa ReynoldsAug 19, 2025
    What to do if Interface TS14 Security Sensors have no signal?
    • A
      Andrew ThomasAug 19, 2025
      If your Interface Security Sensors have no signal, it could be due to a couple of reasons. First, check if there is no sensor excitation; if so, connect the excitation. Second, ensure the signal output is connected correctly; if not, connect the output correctly.
  • K
    krausemaryAug 27, 2025
    Why Interface Security Sensors does not react to torque?
    • C
      Christina RandallAug 27, 2025
      If your Interface Security Sensors are not reacting to torque, consider the following possibilities: 1. The shaft may not be clamped correctly; ensure it is properly clamped. 2. There might be no power supply; connect the power supply. 3. The cable could be defective; repair the cable. 4. The connector may be connected incorrectly; ensure it is connected properly.
  • N
    Nicholas HansonSep 3, 2025
    How to fix signal dropouts and zero point tolerance issues in Interface TS14 Security Sensors?
    • E
      eric34Sep 3, 2025
      To address signal dropouts and zero point tolerance issues in your Interface Security Sensors: * Inspect the cable for defects and repair if necessary. * Ensure the shaft is mounted correctly, without distortion. * Release the shaft string from any distortion. * Reduce any strong lateral forces acting on the sensor.