EasyManua.ls Logo

Intergas Combi Compact HRE 24/18 - User Manual

Intergas Combi Compact HRE 24/18
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Intergas Heating Ltd 1
Combi Compact
HRE 24/18
(G.C. 47-291-01)
HRE 28/24
(G.C. 47-291-02)
HRE 36/30
(G.C. 47-291-03)
HRE 36/40
(G.C. 47-291-04)
Installation, service
and user instructions
Please read these installation instructions carefully before installing and using
the appliance. Keep these installation instructions with the appliance.
Always act in accordance with the instructions indicated.

Table of Contents

Other manuals for Intergas Combi Compact HRE 24/18

Questions and Answers

  • J
    James MillerSep 3, 2025
    What to do if my Intergas Combi Compact HRE 24/18 Boiler displays sensor fault S1?
    • C
      Christopher SmithSep 3, 2025
      If your Intergas Boiler shows a sensor fault S1, check the wiring for any breaks and replace S1 if necessary.
  • B
    bakercrystalSep 1, 2025
    What to do if there is flame detection fault in Intergas Boiler?
    • K
      Kathryn BishopSep 2, 2025
      If you're getting a flame detection fault on your Intergas Boiler, try these solutions: * Replace the ignition cable and spark plug cap. * Replace the ignition unit. * Replace the boiler controller.
  • J
    jennifer25Aug 31, 2025
    Why is my Intergas Boiler's CH not reaching the set temperature?
    • C
      christopher54Aug 31, 2025
      If the central heating (CH) in your Intergas Boiler isn't reaching the set temperature, consider these steps: * Check and adjust the room thermostat setting to 0.1A if it's incorrect. * Increase the CH temperature if it's too low. Check the outside sensor for short circuiting and rectify if needed. * Increase the pump setting or replace the pump if it's not running correctly or the setting is too low. * Ensure there is circulation in the installation; at least 2 or 3 radiators must be open. * Adjust the power if the boiler power hasn't been correctly set for the installation (refer to setting maximum CH power). * De-scale or flush the heat exchanger on the CH side if there's no heat transfer due to lime scale or fouling.
  • D
    Daniel JohnsonAug 29, 2025
    Why does the hot water from my Intergas Combi Compact HRE 24/18 not reach temperature?
    • S
      Sara GrantAug 29, 2025
      If your Intergas Boiler's hot water isn't reaching the desired temperature, consider the following: * Adjust the inlet assembly if the DHW flow is too high. * Set the hot water circuit depending on the desired temperature, if the temperature setting for the water circuit is too low. * Descale or flush the exchanger DHW side if there's no heat transfer due to lime scale or fouling in the heat exchanger DHW side.
  • C
    Christopher ParsonsAug 27, 2025
    Why is the burner resonating in my Intergas Combi Compact HRE 24/18 Boiler?
    • C
      Cheryl SmithAug 27, 2025
      If your Intergas Boiler's burner is resonating, consider these potential causes: * The gas supply pressure may be too low. The house pressure switch may be faulty; contact the gas company. * There might be recirculation of combustion gasses; check the gas flue and the air supply. * The gas/air adjustment might not be correctly set; check the setting (refer to gas/air adjustment guidelines).
  • H
    Hannah DavisAug 26, 2025
    Why is my Intergas Boiler not producing hot water (DHW)?
    • R
      Rachel SmithAug 26, 2025
      If your Intergas Boiler is not providing hot water, consider the following: * Replace the flow switch if the DHW flow is less than 2.0 l/min. * Check the wiring according to the diagram if there's no current at the flow switch (5V DC). * Replace S3 if the burner isn't firing on DHW. * Refer to the 'burner does not ignite' section if the burner isn't igniting.
  • S
    schultzcharlesAug 25, 2025
    Why does my Intergas Combi Compact HRE 24/18 Boiler burner ignite noisily?
    • S
      Sheena PooleAug 25, 2025
      If your Intergas Boiler's burner ignites noisily, it could be due to several reasons: * The gas supply pressure might be too high. The house pressure switch may be faulty; contact the gas company. * The ignition electrode gap may be incorrect; check the ignition electrode gap. * The gas/air adjustment may not be correctly set; check the setting (refer to gas/air adjustment guidelines). * There might be a weak spark; the spark gap should be approximately 4.5 mm.
  • K
    Kevin LopezAug 22, 2025
    Why is there no heating (CH) in my Intergas Combi Compact HRE 24/18?
    • A
      Ashley LoweryAug 23, 2025
      If your Intergas Boiler isn't providing heat, consider the following troubleshooting steps: * Replace the thermostat if it's faulty. * Check the wiring against the diagram. * Check the connector X4 if there's no current (24 V). * Replace the faulty manager. * Check the power supply at connector X2. * Replace the faulty pump if it's not running. * Replace sensor S1 or S2 if the burner isn't firing on CH. See fault code. * Refer to the 'burner does not ignite' section if the burner isn't igniting.

Summary

Safety Regulations

Installer IMPORTANT POINTS

Key Installation Guidelines

Highlights critical points for installers, including user instruction and benchmark compliance.

Key Installation and Commissioning Checks

Lists essential checks for installers regarding user instruction, benchmark logbook, and gas safety.

Installation

Appliance Installation Steps

Guides through unpacking, fitting condensate trap, and connecting flue pipes.

Components

Connection

Central Heating System Connection

Details connecting the central heating system, including required components like drain taps.

Domestic Hot Water Connection

Guides connecting the DHW installation and explains flow resistance and minimum pressure requirements.

Electrical Connection

Wiring and Terminal Connections

Details electrical connections for thermostats, sensors, and mains power supply.

Thermostat and Sensor Wiring Details

Provides specific wiring instructions for on/off, OpenTherm thermostats, and sensors.

Condensate Disposal

Flue system

Flue Pipe and Air Supply

Describes the concentric flue adapter, air supply, and approved flue products.

Commissioning the Appliance

Filling and Venting the System

Guides through filling and venting the central heating and hot water systems.

Combustion Checks and Flue System Verification

Covers combustion checks, flue system integrity, and proceeding to operation.

Startup and System Checks

Details the appliance startup procedure, pressure checks, and temperature differences.

Gas Supply Checks

Details procedures for checking gas supply pressure and performing initial boiler firing.

Setting and Adjustment

Direct Operation via Panel

Explains direct operation of functions like on/off, DHW comfort, and resetting via the control panel.

Service Code and Parameter Settings

Guides on accessing and adjusting parameters using the service code for various settings.

Checking Flue Gas at Maximum Power

Guides on measuring flue gas O2/CO2 levels at maximum output for combustion analysis.

Checking Flue Gas at Minimum Output

Details measuring flue gas O2/CO2 levels at minimum output for combustion analysis.

Correcting Gas-Air Ratio on Minimum Power

Explains how to adjust the gas-air ratio on minimum power using the adjustment screw.

CO2 Adjustment and Protection

Covers CO2 adjustment at minimum power and protection of adjustment screws.

Temperature Settings

Details how to set maximum CH supply temperature and DHW temperature.

Faults

Fault Code Identification and Solutions

Lists common fault codes, their display, and possible solutions for troubleshooting.

Maintenance

Electrical Connections

Warranty Conditions

GAS BOILER SYSTEM COMMISSIONING CHECKLIST

Commissioning Checklist

A checklist for competent persons to complete for boiler installation and commissioning compliance.

SERVICE RECORD

Intergas Combi Compact HRE 24/18 Specifications

General IconGeneral
ModelCombi Compact HRE 24/18
CategoryBoiler
Efficiency93%
Weight32 kg
Boiler TypeCombi
MountingWall Mounted
ERP RatingA
Max. working pressure3 bar
FuelNatural Gas
Efficiency (%)93

Related product manuals