EasyManua.ls Logo

Interlogix GS960 User Manual

Interlogix GS960
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© 2018 UTC Fire & Security Americas Corporation, Inc. 1 / 14 P/N 422-6367-ML • REV E • ISS 03DEC18
GS960 Acoustic Glass Break Detector
Installation Sheet
EN
DE
SV
1
2
3
4
5
6
7
(1)
(4)
(5)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(6)
(1)
(2)
(5)
(4)
(3)
ON
1
2 3
(1) (2) (2) (3)
(1)
(2)
(3)
(4)
Question and Answer IconNeed help?

Do you have a question about the Interlogix GS960 and is the answer not in the manual?

Interlogix GS960 Specifications

General IconGeneral
Power Supply/Operating Voltage9 to 16 VDC
Alarm OutputNormally Closed (NC) Relay
Tamper Output/ProtectionNormally Closed (NC) Relay
Operating Temperature14° to 122°F (-10° to 50°C)
Humidity Range95% RH, non-condensing
Mounting Height7 ft (2.1 m) minimum
OutputRelay

Summary

Detector Description and Features

Description

Explains GS960 as an acoustic glass break detector and its advanced technology.

Connection to a 24-hour loop

Details the detector's continuous supervision and resistance to acoustic disturbances.

Signalled Events

Outlines signals for intrusion relay and tamper micro-switch events.

Special Tools

Recommends the GS960-TR tester for installation in complex acoustic environments.

Installation and Configuration

Installation Steps

Provides step-by-step instructions for mounting and wiring the detector.

DIP Switch Settings

Explains DIP switch functions for intrusion relay mode and range setting.

Suggested Detector Settings

Provides recommended settings based on window design and glass type.

Testing, Calibration, and Operation

Closing the Detector

Instructions for reassembling the detector cover after installation.

Testing and Calibrating with GS960-TR

Guide on using the GS960-TR tester for optimal calibration and function.

Digital Room Compensation Procedure

Details the DRC procedure for setting the detector's range and sensitivity.

Protecting Multiple Windows

Guidance on using one detector for several windows within the coverage area.

Detector Indicators and Troubleshooting

Understanding LED Operation

Explains LED states during normal operation and GS960-TR tester use.

Troubleshooting Common Issues

Addresses problems like detector non-response or permanently lit LEDs.

Specifications

Lists technical details including glass type, range, voltage, and output ratings.

Regulatory Information

Details manufacturer, EU representative, certifications, and directives compliance.

Related product manuals