2. Deselect Enable and click Save to remove the default certificate.
3. To create a self-signed certificate:
Select the Create Self-signed Certificate radio button and then click Create. Enter
the country, host name/IP, validity, and the other information requested.
—or—
To create a certificate request:
Select the Signed Certificate is available, Start the installation directly radio
button and then click Create. Upload the certificate to the device.
—or—
To create an authorized certificate:
Select the Create the certificate request first and continue the installation as
radio button and then click Create. Fill in the required information in the popup
window. Download the certificate request and submit it to the trusted certificate
authority (such as Symantec or RSA) for signature. After receiving the signed valid
certificate, upload the certificate to the device.
4. Click OK to save the settings.
To define the QoS parameters:
1. From the menu toolbar, click Configuration > Network > Advanced Settings >
QoS.
2. Configure the QoS settings, including Video/Audio DSCP, Event/Alarm DSCP,
and Management DSCP. The valid value range of the DSCP is 0-63. The higher
the differentiated services code point (DSCP) value, the higher the priority of the
service.
3. Click Save to save changes.
Video/Audio
Adjust the video and audio recording parameters to obtain the required picture quality
and file size.
TruVision 81 Series IP Camera Configuration Manual 21