Electronic 4-Circuit
Astronomic 365/7-Day Time Switch
Installation and Setup Instructions
With 100-Hour Backup
Federal Communications Commission (FCC) Notice for ET2000 Series Time Switches
Description
This document explains the setup and conguration of the Intermatic ET2845
4-Circuit Electronic Astronomic 365/7-Day Time Switch. The ET2845 time switch
automatically switches loads according to the weekly schedule that is entered.
The time switch can support up to 48 xed ON and 48 xed OFF events (96 total)
and up to 8 Astro events. Each xed event can be applied to any combination of
circuits and days.
The time switch features an LCD and panel-mounted control buttons to set,
review, and monitor the time switch functions, including setting date and time,
schedule creation, enabling or disabling Daylight Saving Time (DST) and
conguring DST switchover dates.
Follow these instructions to complete the installation and programming of the
ET2845 time switch.
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause
undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and radiates radio frequency energy and, if
not installed and used in ac-cordance with instructions, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference that requires the user to correct at his or her own expense.
MODELS ET2845C, ET2845CR, ET2845CP
Shown in indoor/outdoor
lockable metal enclosure
NOTICE
Do NOT touch circuit board components, contact can create a static discharge, which can damage these electronic components.
Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
More than one circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
For plastic enclosures, bonding between conduit connections is not automatic and must be provided as part of the installation.
Installation and/or wiring must be in accordance with National and Local Electrical Code requirements.
Use #14-#8 AWG wires, rated at least 105°C - COPPER conductors ONLY.
If the power disconnect point is out of sight, lock it in the OFF position and tag it to prevent unexpected application power.
Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fitting conduit and
outlet boxes) are to be used.
Do not remove insulator that is covering terminals.
Do NOT exceed maximum current carrying capacity.
KEEP DOOR CLOSED AT ALL TIMES when not servicing.
Risk of Fire or Electric Shock
WARNING
Question and Answer IconNeed help?

Do you have a question about the Intermatic ET2845C and is the answer not in the manual?

Intermatic ET2845C Specifications

General IconGeneral
BrandIntermatic
ModelET2845C
CategoryTimer
LanguageEnglish

Summary

Safety Warnings and Product Description

Risk of Fire or Electric Shock

Critical safety precautions to prevent electric shock and fire hazards during installation and servicing.

Product Description

Overview of the Intermatic ET2845 time switch features, capabilities, and programming.

FCC Compliance Notice

Regulatory information regarding radio frequency interference for the ET2000 Series.

Installation and Initial Setup

Installation Procedure

Step-by-step instructions for physically mounting and wiring the time switch.

Wiring Diagrams

Visual guides illustrating various electrical connection configurations for the time switch.

Initial Setup Steps

Configuration of output, date, time, Daylight Saving Time (DST), and time zones.

Programming Overview

General steps for programming events, schedules, and settings on the time switch.

Setting Astro Zone and Time

Configuring geographical location for astronomic events and setting the device's time.

Event and Mode Programming

Setting Astronomic OnOff Events

Configuring ON/OFF events based on sunset and sunup times for each circuit.

Setting Fixed Timed Events

Programming specific ON/OFF times for circuits on selected days of the week.

Setting Holidays

Programming date ranges to override normal schedules with special ON/OFF events.

Setting Operating Mode

Selecting the operational mode: AUTO, ENERGY SAVER, or MANUAL.

Advanced Operations and Specifications

Event and Memory Management

Procedures for deleting individual events and clearing the entire time switch memory.

USB Data Transfer Operations

Instructions for writing and reading program data to and from a USB memory stick.

USB Error Codes

Description of error codes encountered during USB operations.

Technical Specifications

Details on input voltage, power consumption, contact ratings, wire size, and enclosures.