8 Mini-Wave PE4 Installation Guide
Copyright © 2006 Intermatic, Inc.
The Wireless Hand-Held Transceiver can only communicate with the Panel-Mounted Transceiver
(PE650) and Transceiver Repeater Module (HA04C), and is compatible with no other hardware.
In addition, when the components of a specic system are linked together into a network,
communication with another neighboring system cannot occur. Up to ve PE950 units can be
used in a single installation.
Eight-Setting ON/OFF Clock (PB313EK)
The Eight-Setting ON/OFF Clock (PB313EK) that accompanies the Mini-
Wave PE4 system provides timer control of Relay 1 or Relay 2, depending
on the version, for one of the Pump/Valve Control mechanisms. An
additional clock can be installed in the steel enclosure if desired, providing
timer control of a second circuit.
The clock can be programmed for up to eight ON/OFF settings.
35-ft. Antenna Extension Cable Assembly (PA121)
When a structure impedes transmission between the Panel-Mounted
Transceiver and Hand-held Transceiver(s), you can use the 35-ft.
Antenna Extension Cable Assembly (PA121) to relocate the antenna
from the Panel-Mounted Transceiver to the area of operation, ensuring that communication
between the Hand-Held unit and the control center is successful. The Mini-Wave includes this
antenna extension cable assembly.
OMRON Relay w/24VDC Coil & 2-pin Connector (143T145A)
There are four OMRON Relay Assemblies (143T135A) in the Mini-Wave
PE4 Control System which switch either 120V or 240V loads. These relays
are replaceable and can be ordered separately.
OMRON Relay w/24VAC Coil & 3-pin Connector (PA120)
When an additional relay is desired for circuit #3 it must be plugged into
any of the two-actuator ports on the upper control board. Since you will
be using the actuator circuit to power this new relay, the relay must have a
24VAC coil and a three-pin connector. The PA120 supports this installation
and must be used for this application.
NOTE: DO NOT USE A RELAY WITH A 24VDC COIL FOR CIRCUIT #3. The relay will chatter
and possibly damage the equipment it controls.
CONTACT RATINGS – EACH CIRCUIT
30A Resistive, 120/240VAC., 50/60 Hz
1.5 HP @ 120VAC., 50/60 Hz
3.0 HP @ 240VAC., 50/60 Hz
10 Amp Tungsten, 120/240VAC, 50/60 Hz
CONTACT RATINGS – EACH CIRCUIT
30A Resistive, 120/240VAC., 50/60 Hz
1.5 HP @ 120VAC., 50/60 Hz
3.0 HP @ 240VAC., 50/60 Hz
10 Amp Tungsten, 120/240VAC, 50/60 Hz
CONTACT RATINGS – EACH CIRCUIT
30A Resistive, 120/240VAC., 50/60 Hz
1.5 HP @ 120VAC., 50/60 Hz
3.0 HP @ 240VAC., 50/60 Hz
10 Amp Tungsten, 120/240VAC, 50/60 Hz
CONTACT RATINGS – EACH CIRCUIT
30A Resistive, 120/240VAC., 50/60 Hz
1.5 HP @ 120VAC., 50/60 Hz
3.0 HP @ 240VAC., 50/60 Hz
10 Amp Tungsten, 120/240VAC, 50/60 Hz