EasyManuals Logo

Intermec EasyCoder 3400 Getting Started Guide

Intermec EasyCoder 3400
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
10
RS-232 Null Modem Cable for 9-pin PC (Intermec Part Number 048693)
RS-232 Null Modem Cable for 25-pin PC (Intermec Part Number 048668)
SHIELD
PC
PRINTER
25-PIN (SOCKET) D-SUB
METAL BACKSHELL
25-PIN (PLUG) D-SUB
METAL BACKSHELL
NOTE: The metal backshell is connected directly
to the shield to achieve electrostatic discharge
(ESD) immunity.
CHASSIS GROUND
TRANSMITTED DATA
RECEIVED DATA
REQUEST TO SEND
CLEAR TO SEND
DATA SET READY
GROUND
DATA TERMINAL READY
CARRIER DETECT
CHASSIS GROUND
RECEIVED DATA
TRANSMITTED DATA
CARRIER DETECT
DATA TERMINAL READY
GROUND
DATA SET READY
CLEAR TO SEND
1
2
3
4
5
6
7
20
8
1
3
2
8
20
7
6
4
5
3440G.053
SHIELD
AT
PRINTER
9-PIN (SOCKET) D-SUB
METAL BACKSHELL
25-PIN (PLUG) D-SUB
METAL BACKSHELL
NOTE: The metal backshell is connected directly
to the shield to achieve electrostatic discharge
(ESD) immunity.
RECEIVED DATA
TRANSMITTED DATA
CLEAR TO SEND
REQUEST TO SEND
DATA TERMINAL READY
DATA SET READY
CARRIER DETECT
GROUND
CHASSIS GROUND
TRANSMITTED DATA
RECEIVED DATA
CARRIER DETECT
DATA SET READY
DATA TERMINAL READY
CLEAR TO SEND
REQUEST TO SEND
GROUND
2
3
8
7
4
6
1
5
1
2
3
8
6
20
5
4
7
3440G.054
15
3440G.027
ON
O = OFF
1 = ON
Multi-drop Address Selection
*A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
0
1
2
3
4
5
Protocol Selection
XON/XOFF*
Intermec Protocols
XON/XOFF Selection
No Status Response*
With Status Response
DT/TTR
Direct Thermal*
Thermal Transfer
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
1
O
O
1
1
O
O
1
1
O
O
1
1
O
O
1
1
O
O
1
1
O
O
1
1
O
O
1
1
O
O
1
1
O
O
O
O
1
1
1
1
O
O
O
O
1
1
1
1
O
O
O
O
1
1
1
1
O
O
O
O
1
1
1
1
O
O
O
O
O
O
O
O
1
1
1
1
1
1
1
1
O
O
O
O
O
O
O
O
1
1
1
1
1
1
1
1
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
O
1
O
1
O
1
Default settings are noted with an *
Bottom Bank Switch Number
1 2 3 4 5 6 7 8
OFF
1 2 3 4 5 6 7 8
O = OFF
1 = ON
O
1
O
1
O
1
O
1
O
O
1
1
O
O
1
1
O
O
O
O
1
1
1
1
O
1
O
1
O
O
1
1
O
1
O O
Default settings are noted with an *
Top Bank Switch Number
ON
OFF
Baud Rate Selection
19,200
9,600*
4,800
2,400
1,200
38,400
57,600
reserved
Parity Selection
Even*
Odd
None
None
Number of Data Bits
7 Bit*
8 Bit
Reserved
DIP Switch Settings

Other manuals for Intermec EasyCoder 3400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder 3400 and is the answer not in the manual?

Intermec EasyCoder 3400 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder 3400
CategoryPrinter
LanguageEnglish

Related product manuals