5.2. Overflow
This message will be displayed, if at closed solenoid valve and running hydraulic pump
the oil level reached the highest level switch for a certain amount of time.
The reaction time is determined by the chosen viscosity during the starting procedure
The reasons for this error could be the following:
- chosen a wrong viscosity
- high vacuum
- defect hydraulic pump
- clogged pressure line
5.3. Filter clogged
This message indicates a clogged particulate filter element.
Exchange filter element and restart the system
5.4. No lubricating oil in v-pump
Indicates a low oil level in the vacuum pump
This can be caused by clogging the coalescent element of the vacuum pump and the
loss of oil related to that.
Exchange the coalescent element, fill up oil and restart the system.