4
At mobile units set the locking brake before operation!
The air oulet must be open!
At leakages please dispose the oil professional (oil binding agent)!
The IFPM/S-units are only for indoor operation and not for outdoor
installation!
1.3. Intended use
• The IFPM/S-units are oil purification systems, which take oil from a reservoir with a
hoseline or a pipeline. This oil will be purified of water, solid contamination and gases.
• The purified oil will be pumped back into the same reservoir.
• The solid contamination will be separated by the filter element, the removed water will
be blown out as humid air into the atmosphere.
• The removed gases also will be blown into the atmosphere.
• The unit works unattended after starting it.
2. Technical data
Operating temperature: 20...80°C
Ambient temperature: 0...40°C
Viscosity: 12...700 mm²/s
Noise pressure level: 69 dB (Af)*
Degree of protection: IP54
Circulation flow rate:
IFPM21: 20 l/min*
IFPM31: 30 l/min*
IFPM/S71: 70 l/min*
IFPS101: 100 l/min*
Mass:
IFPM21: 315 kg
IFPM31: 325 kg