TROUBLESHOOTING (continued)
LED PANEL
CODE
PROBLEM SOLUTION
LED Panel Code Flash & Alarm On (
NOTE
: Always turn off the power before cleaning and servicing).
E90
•
Nowaterow.
•
Turn off and unplug the control unit.
•
Ensure the outlet cover grid is clean and free from obstructions.
•
Clean or replace the cartridge, see Maintenance and Storage section.
•
Ensurethein/outletconnectionsonthespatubandlterpumparenot
blocked.
•
Keep the spa water properly sanitized to ensure a clean and unclogged
ltercartridge.
•
Press the button to turn off the unit. Release trapped air by
unscrewing the drain valve cap on the control base side with a coin.
Airhasbeenreleaseonceasteadystreamofwaterisowingoutfrom
the drain valve. Wait for 15 seconds and screw the drain valve cap
back. Press the button to activate the control panel buttons, and
thenrunthelterfunctionbypressingthebuttontopushoutany
remaining air in the system.
•
If problem persists, contact Intex Service Center.
E91
•
Dirt or scale on titanium plates.
•
Low salt level / No salt.
•
Electrolytic cell cord is loose.
•
Possible electrolytic cell failure.
•
Remove the electrolytic cell for inspection. Clean it if necessary. See
“Maintenance”.
•
Add salt. See “Salt Level Information”.
•
Ensurethatthecellcordispluggedrmlyintothecellreceptacle.
•
Contact Intex Service Center. Replace the cell if needed.
E92 •
High salt level.
•
Partiallydrainthepoolandrellitwithfreshwater.See“SaltLevel
Information”.
E94
•
Water temperature too low.
•
If the ambient temperature is below 4°C (39°F), we recommend not to
use the spa.
•
Turn off and unplug the control unit, add some warm water to raise the
spa water temperature above 5°C (41°F), then press the button to
heat up the water to the desired temperature.
•
If problem persists, contact Intex Service Center.
E95
•
Water temperature is
around 50°C (122°F).
•
Turn off and unplug the control unit. When the water has cooled down,
plug the RCD and restart all over again.
•
Turntheheateroff,thenpressthelterandjetbuttonstolowerthe
water temperature.
•
If problem persists, contact Intex Service Center.
E96
•
System Error.
•
Turn off and unplug the control unit. Plug the RCD and restart
all over again.
•
If problem persists, contact Intex Service Center.
E97 •
Dry-reProtection.
•
Contact Intex Service Center.
E99
•
Water temperature sensor broken.
•
Contact Intex Service Center.
END
•
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The
rapidheatingandwaterltration
functions are disabled.
•
Pressthebuttontore-activethelterpump.