Do you have a question about the Invacare Platinum XL and is the answer not in the manual?
Brand | Invacare |
---|---|
Model | Platinum XL |
Category | Oxygen Equipment |
Language | English |
Defines DANGER, WARNING, and CAUTION signals used in the manual.
States that document information is subject to change without notice.
Provides safety precautions for oxygen therapy and general use of the concentrator.
Details routine preventive maintenance and who should perform it.
Lists specific safety warnings related to electrical hazards and fire prevention.
Guides on checking the battery-free power loss alarm functionality.
Describes the air flow and operational steps within the concentrator.
Explains the technical details and operation of the O2 sensor.
Step-by-step instructions for detaching the main cabinet from the base assembly.
Procedure for cleaning the unit's cabinet filters based on environmental conditions.
Instructions for checking and replacing the unit's outlet HEPA filter.
Steps for replacing the compressor's inlet filter, including model-specific label instructions.
Detailed steps for removing and installing the main compressor unit.
Instructions for replacing the capacitor on 5-Liter and 10-Liter models.
Guide for rebuilding specific compressor models using a kit.
Steps for disassembling the compressor and removing its heads and valve plates.
Instructions for rebuilding the Gast compressor model used in Platinum XL.
Instructions for replacing the Pressure Equalization (P.E.) valve assembly.
Procedure for replacing the sieve beds, including safety precautions.
Instructions for installing and orienting check valves correctly.
Steps for removing and installing the pressure regulator, noting flow direction.
Procedure for adjusting the regulator pressure to specified levels.
Instructions for removing and installing the heat exchanger.
Step-by-step guide to remove the control panel assembly from the unit.
Procedure for removing and installing the unit's cooling fan, noting airflow direction.
Instructions for replacing the Printed Circuit board, including static precautions.
Steps for removing and installing the transformer assembly.
Procedure for replacing the unit's power On/Off switch.
Instructions for removing and installing the flowmeter.
Steps for removing and installing the hour meter.
Procedure for replacing the 4-way valve assembly.
Instructions for replacing the manifold assembly on older units.
Instructions for replacing the manifold assembly on newer units with Y-tube mufflers.
Steps for replacing poppets and O-rings within the pilot valve.
Explains the indicator lights and alarms related to oxygen purity monitoring.
Explains indicator lights for LX models without the O2 sensor.
General introduction to timing adjustments for various models.
Procedure for the automatic tuning process of the P.E. valve timing.
Steps for manually adjusting the P.E. valve timing.
Procedure for testing the unit for pneumatic leaks using a solution.
Procedure to test the power loss alarm functionality.
Guides on testing low pressure alarms via two different methods.
Steps to test high pressure and main valve coil alarms.
Procedure for testing the oxygen sensor alarm.
Instructions for installing a kit and checking sieve bed pressures.
Steps for installing the sieve bed pressure tap-in kit.
Procedure for performing pressure tests on the sieve beds.
Steps to complete after performing sieve bed pressure tests.