BPD series PV pumping inverter Function parameters
44
Function
code
Name
Detailed description
Default
Modify
switching to
PV input
delay time of P15.21, it can be switched to PV input
through relay output. In order to avoid repeated
switching, the threshold needs to be higher than
the threshold of P15.30.
If the value is 0.0, the function is disabled.
The default value depends on model.
For models of 220V:
0.75kW: 100.0V
1.5kW, 2.2kW and 4kW: 120.0V
For models of 380V:
2.2kW5.5kW: 240.0V
on
model
P15.32
Empty-water
delay
010000s
5s
P15.33
Wake-up delay
of empty
-water
010000s
20s
P17 Group State viewing
P17.38
Current of the
main winding
Current of the main winding when applying the
capacitance-removed mode to control the 1PH
motor
0.00100.00A
0.00A
P17.39
Current of the
secondary
winding
Current of the secondary winding when applying
the capacitance-removed mode to control the 1PH
motor.
0.00100.00A
0.00A
P18 Group Parameters for viewing PV inverter states
P18.00
PV reference
voltage
MPPT is set at the inverter side. This value is
specified at the inverter side.
P18.01
Current PV
voltage
It is the PV input voltage provided by the boost
module.
P18.02
Bus voltage
reference
It is used to set the reference voltage of the bus
when PV input is adopted.