Goodrive300 Series VFD    Function parameters 
79 
Detailed instruction of parameters 
output   
26: Voltage establishment finished   
27–30: Reserved 
Polarity of 
output 
terminals 
The function code is used to set the pole of the 
output terminal.   
When the current bit is set to 0, the input terminal 
is anode. 
When the current bit is set to 1, the input terminal 
is cathode. 
The  function  code  defines  the  corresponding 
delay  time  of  the  electrical  level  change  during 
the programmable terminal switching on and off.   
Y electrical level
Y valid
Invalid
 
Switch-on
delay
 
Invalid
Valid  
Switch-off
delay
 
 
Setting range: 0.000–50.000s 
Note:  P06.08  and  P06.08  are  valid  only  when 
P06.00=1. 
HDO 
switch-off 
delay time 
RO1 switch-off 
delay time 
RO2 switch-off 
delay time 
0: Running frequency   
1: Set frequency   
2: Ramp reference frequency   
3: Running rotation speed (relative to 2 times the 
synchronous rotation speed of the motor) 
4:  Output  current  (relative  to  2  times  the  rated 
current of the VFD) 
HDO 
high-speed 
pulse output