Goodrive170-PV Series Solar Pump Inverter Power frequency & PV switching solution
-63-
Appendix C Power frequency & PV switching solution
C.1 Solution introduction
Generally, inverters do not allow simultaneous connection of power frequency and PV. If
such simultaneous connection is required, switching control circuit needs to be
configured externally. The following figure shows a solution for reference.
Figure C-1 Inverter power frequency & PV switching solution
AC
input
PV
input
(+)
S
T
DC breaker QF2
AC breaker (QF1) AC contactor (KM1)
U
V
W
Surge Protection Device (SPD)
Fuse (FU)
M
Pump motor
R
S
T
R
(+)
(-)
GD170-PV
inverter
B
C
A
+
-
Diode (D)
Voltage detection
circuit
PV+
PV-
PV+
S
COM
HDI
COM
220V
RO1B
RO1C
~
KM1
QH100-PV switching module
PE
A1 A2
See section C.1.1 for specifications and model selection of QH100-PV switching module,
whose necessary low-voltage apparatuses include QF1, KM1, QF2, FU, and SPD. See
section C.1.2 for model selection information.
C.1.1 QH100-PV switching module
C.1.1.1 Model and specification
QH100 055A 4 PV
Field
Sign
Description
Content
Product series
abbreviation
Product series
abbreviation
QH100 series power frequency & PV
switching module
Rated current
Power range for
adaptive inverter
055Aapplies to inverters of 15kW
110Aapplies to inverters of 18.537kW
Voltage class
Voltage class
4: AC 3PH 380V(-15%)440(+10%)