Goodrive300 Series VFD Function parameters
120
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P15.24
Temporarily
variable 1 for
PZD sending
065535
0
P15.25
Fault tiem of
DP
communicatio
n overtime
0.0 (invalid),0.160.0s
When this function code is set as 0.0, this
function is invalid.
When the function code is set as nonzero value, if
the internal time between two adjent
communications exceeds the communication
overtime, the system will report "PROFIBUS
communication fault" (E-DP).
0.0s
P15.26
Fault tiem of
CANopen
communicatio
n overtime
0.0(invalid), 0.160.0s
When this function code is set as 0.0, this
function is invalid.
When the function code is set as nonzero value, if
the internal time between two adjent
communication exceeds the communication
overtime, the system will report "CANopen
communication fault" (E-CAN).
0.0s
P15.27
CANopen
baud rate
0: 1000k
1: 800k
2: 500k
3: 250k
4: 125k
5: 100k
6: 50k
7: 20k
0
P16 Group Ethernet function
P16.00
Speed setting
of the Ethernet
communicatio
n
0: Self-adapting
1: 100M full duplex
2: 100M semiduplex
3: 10M full duplex
4: 10M semiduplex
The function code is used to set the Ethernet
communication speed.
0
P16.01
IP address 1
0255
Set the IP address of Ethernet communication.
192
P16.02
IP address 2
168

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive300 Series and is the answer not in the manual?

INVT Goodrive300 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals