EasyManua.ls Logo

INVT Goodrive350-19 Series - Page 307

INVT Goodrive350-19 Series
540 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive350-19 series VFD Function parameter list
- 300 -
Function
code
Name
Description
Default
value
Modify
card in card slot 2
P16.26
Identification time
for the extension
card in card slot 3
0.0600.0s
If it is set to 0.0, offline fault will not be detected
0.0s
/
P16.27
Communication
timeout period of
extension card in
card slot 1
0.0600.0s
If it is set to 0.0, offline fault will not be detected
0.0s
/
P16.28
Communication
timeout period of
extension card in
card slot 2
0.0600.0s
If it is set to 0.0, offline fault will not be detected
0.0s
/
P16.29
Communication
timeout period of
extension card in
card slot 3
0.0600.0s
If it is set to 0.0, offline fault will not be detected
0.0s
/
P16.30
P16.69
See GD350 communication extension card operation manual for details.
P17 State-check functions
Function
code
Name
Description
Default
value
Modify
P17.00
Set frequency
Displays current set frequency of the VFD.
Range: 0.00HzP00.03
50.00Hz
P17.01
Output frequency
Displays current output frequency of the VFD.
Range: 0.00HzP00.03
0.00Hz
P17.02
Ramps reference
frequency
Displays current ramps reference frequency of the
VFD.
Range: 0.00HzP00.03
0.00Hz

Table of Contents

Related product manuals