Goodrive350-19 series VFD Commissioning
- 41 -
Function
code
Name
Setting
Remarks
P90.06
Graded multi-step speed
reference 0
10.0%
Corresponding to the max. frequency
P90.07
Graded multi-step speed
reference 1
30.0%
Corresponding to the max. frequency
P90.08
Graded multi-step speed
reference 2
50.0%
Corresponding to the max. frequency
P90.09
Graded multi-step speed
reference 3
70.0%
Corresponding to the max. frequency
P90.10
Graded multi-step speed
reference 4
90.0%
Corresponding to the max. frequency
P90.14
Forward brake release
torque
50.0%
Corresponding to the motor rated
torque
P90.15
Reverse brake release
torque
30.0%
Corresponding to the motor rated
torque
P90.16
Forward brake release
frequency
3.00Hz
P90.17
Reverse brake release
frequency
3.00Hz
P90.18
Forward brake closing
frequency
3.00Hz
P90.19
Reverse brake closing
frequency
3.50Hz
P90.20
Delay before forward
brake release
0.000s
P90.22
Delay after forward brake
release
0.500s
P90.24
Delay before forward
brake closing
0.000s
P90.26
Delay after forward brake
closing
0.100s
P90.30
Torque verification fault
detection time
2.000s
P90.31
Enabling the monitoring on
brake status
1
Enable the brake current monitoring
(and brake feedback detection)
P91.08
Light load speed boost
function selection
2
Constant power speed limit
Note: The macro parameter table does not contain some parameters that are factory default

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive350-19 Series and is the answer not in the manual?

INVT Goodrive350-19 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive350-19 Series
CategoryDC Drives
LanguageEnglish

Related product manuals