C
HAPTER
4
| Basic Management Tasks
Resetting the System
– 122 –
ES-3052 Series
COMMAND USAGE
This command resets the entire system.
To retain all configuration information stored in non-volatile memory,
click the Save button prior to resetting the system.
When the system is restarted, it will always run the Power-On Self-Test.
PARAMETERS
The following parameters are displayed in the web interface:
System Reload Configuration
Reload ModeRestarts the switch immediately or at the specified
time(s).
Immediately – Restarts the system immediately.
In – Specifies an interval after which to reload the switch.
(The specified time must be equal to or less than 24 days.)
hours – The number of hours, combined with the minutes,
before the switch resets. (Range: 0-576)
minutes – The number of minutes, combined with the hours,
before the switch resets. (Range: 0-59)
At – Specifies a periodic interval at which to reload the switch.
DD - The day of the month at which to reload. (Range: 1-31)
MM - The month at which to reload. (Range: 1-12)
YYYY - The year at which to reload. (Range: 2001-2050)
HH - The hour at which to reload. (Range: 0-23)
MM - The minute at which to reload. (Range: 0-59)
Regularly – Specifies a periodic interval at which to reload the
switch.
Time
HH - The hour at which to reload. (Range: 0-23)
MM - The minute at which to reload. (Range: 0-59)
Period
Daily - Every day.
Weekly - Day of the week at which to reload.
(Range: Sunday ... Saturday)