EasyManua.ls Logo

IPS Controllers M720 - Installati; Setup; Tools; Procedure

IPS Controllers M720
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
II. Installaon
A. Setup
1. Turn o all peripheral equipment such as heaters, chemical
feeders, and pumps.
2. Relieve pressure from the ltraon system.
B. Tools
1. Cordless drill
2. 1/4” NPT Tap
3. 7/16” drill bit
4. Masonry drill bit and anchors, or other appropriate fasteners
5. 13/16” wrench or channel-lock pliers
C. Procedure
1. Locaon
a. Wall area with easy access
b. Within 8 feet of feeder
c. At least 10 feet from water edge
d. Close proximity to me clock
e. Within 6 feet of GFCI power source
2. Mounng
Note: The controller and ow cell are factory mounted to the ABS
board for convenience.
a. Securely mount ABS mounng board with M720 controller
and ow cell on wall (vercal installaon).
b. If applicable, securely aach the peristalc pump with the
provided hardware.
11
M720 pH/ORP Controller Owners Manual