C. System Components
1. IPS M720 pH/ORP Controller
a. Allows automac monitoring of pH and ORP levels through
a simple, user-friendly interface, resulng in easier
management of water balance in swimming pools, spas, or
circulang water environments.
b. Can be easily installed into your exisng pool environment
and equipment, or can be customized to your needs.
c. Monitors and displays the pH and ORP levels using LEDs
and digital readouts on the front panel.
In addion, ve separate funcon buons allow simple
pushbuon control of these individual parameters:
1) Mode - Auto or pH Standby (programming),
2) Set Level - pH level to be maintained,
3) Dose Timer - Timed or Connuous feed modes,
4) Delay Time - Delay period aer each Dose Time,
5) pH Cal - pH calibraon.
d. When the pH level rises above (acid feed) or falls below
(base feed) the set level, the controller will acvate the
chemical feeder for the set dose me. Then the set delay
me will occur. This dose and delay me will occur unl
the set level is reached.
e. When the ORP (sanizer) level reaches the set level, the
controller will acvate the chemical feeder for the set dose
me. Then the set delay me will occur. This dose and
delay me will occur unl the set level is reached.
2. Flow Cell with Flow Switch
a. An injecon-molded ow cell with integrated ow-switch
houses the pH and ORP sensors, and partners with the
M720 controller to monitor the pH and ORP levels in the
water.