iv. Use Up/Down buon to increase/decrease pH High
Alert
v. When nished, press Mode buon to connue
f. Low Alert
1. Default: 7.0 pH
2. Selectable range: OFF, 6.8 pH to 7.4 pH (acid feed). A
low alert will occur if the pH level remains below the
Low Alert level for 10 connuous minutes, and will
automacally turn o the Low Alert when the pH level
rises above the low alert level for 1 connuous minute.
During Low Alert, the pH dose output will be disabled.
3. Changing Low Alert seng
i. Press Mode buon to enter pH standby
ii. Press and hold Mode buon and then press Set Level
buon (red pH alert LED will come on) release both
buons. You are now in Set Alerts mode.
iii. Press Dose Time buon to display current Low Alert
iv. Use Up/Down buon to increase/decrease pH Low
Alert
v. When nished, press Mode buon to connue
3. pH Cal
1. Allows pH reading to be adjusted .9 pH up or .9 pH
down from actual sensor reading.
2. Default: 0 pH adjustment
3. To clear all calibraon that may have been entered:
i. Press Mode buon to enter pH standby
ii. Press and hold Mode unl the controller turns o.
iii. Press and hold the pH Cal buon and then the Mode
buon unl the controller turns on. Release both
buons.
iv. Press the Mode buon to connue back to Auto to
see the reading without calibraon.
18
M720 pH/ORP Controller Owner’s Manual