11
Preprogramming mode 3
Preprogramming
To get into the "preprogramming mode": see " Classification according to modes 2 ".
The selection here is generally made by altering, if necessary, the command on the display by means of
" NO " (e.g. " no FC " becomes " FC " after pressing " NO "). Confirm this selection with " E ".
While preprogramming, it is possible to return step by step by pressing the " STOP " button.
PrE = Preprogram (Altering the "Preprogram")
Press " E "
HF = Machine of type HF, WE245/304 or "high spin" WE-machine
FC = Frequency controlled (frequency controlled motor)
Coin = machine with coin mechanism
First, put in the value of the coin meter with the highest value by means of " X,X,X ".
If necessary, move the decimal point by pressing " START ".
By pressing " E " you can proceed to the other coin meters and install them in the same manner.
LECo = Level control (Control of the water level)
This means the program is temporarily stopped until the appropriate water level is reached.
SE-i = Select inlet (Selection of water inlet valves).