17
Preprogramming mode 4
Bu = Buzzer at the end of the program
t = Temperature shown on the display
ACCL = Acceleration
With this it is possible to go through a program rapidly in the "operating mode" with the bottom " E ".
EMEr = Emergency stop
The button " STOP " is used as an emergency stop in the "operating mode".
ALArm
This allows to control an external light or sound source through the exit SOAP 6 . This source can e.g. indicate
the end of a program or soak cycle. However, this reduces the number of soap exits from 6 to 5.
The following steps will not be displayed on the WE machines. On all WE machines, the preprogramming is
now finished and the display returns to StArt .
iS.tilt.XX (Intermediate Spin unbalances)
Indicate the number of unbalances allowed during intermediate spin (from 1 to 15) before the spin cycle is
skipped.
ES.tilt.XX (Final Spin unbalances)
Indicate the number of unbalances allowed during final spin (from 1 to 15) before the spin cycle is skipped.
The preprogramming phase is now finished. The display will return to StArt .