Preprogramming mode 3
HEAt-SYS = Heating System
All machines with hot water feeding can use this temperature modulation technique. This technique consists
of a controlled water feeding -and mixture process which results in most cases in obtaining the correct water
temperature in the wash bath during the filling of the tub. If this function is disabled, a traditional water mixing
procedure will be executed.
The next steps require this function to be either activated or disabled.
Select from:
HEAt (filling and heating system without modulation)
HEAt-Mod (filling and heating system with modulation
Mod (filling procedure consisting only of modulation; no heating system)
If no hot water inlet valves were selected (see SE-i), HEAt will automatically be selected and
HEAt-SYS  will not be displayed.
HECo = Execute heating control (temperature control)
This function will temporarily stop the program while the water is being heated to the programmed temperature
GEntlE = The action and stop times of the drum will be switched while the water is being heated
If the machine is not equipped with a heating system (Mod is selected at HEAt-SYS), the function HECo and
GEntlE will not be displayed.
t °C or t °F = Choice to display temperature in °C or °F.
Add = Additional programs
These 3 options (Cool-down, time stop and soak program) can be installed later on in the programming process.
SoAP = Liquid soap injection