23
Programming mode 4
HECo = Heating control (Temperature control)
If no temperature control is desired, select " no HECo " and press " E ".
If temperature control is desired, select " HECo " and press " E ".
If  Mod  was selected, the display will immediately go to  XX. SE-i .
t XX = Time (Time of the temperature control)
Put in the time when the temperature should be controlled with " X,X " (between " 0 " and the wash time that
was initiated at " Cycle time ") and press " E ".
GEntlE = switching of action and pause time (Put in at " A XX " and " S XX ") during temperature control.
XX. SE-i = Select water inlet valves
Press " E ".
i2 = Inlet 2 (Inlet valve 2) (HF-WE-WE/4) or i1 = Inlet 1 (Inlet valve 1) (HFP machine)
Choose using  NO  if an inlet valve should be selected or not.
Subsequently press  E  to continue to the next inlet valve.
In order to save space, not all inlet valves are drawn here. The action involved are identical to the first inlet.
A description of the function of each inlet valve is provided in chapter 3.
If, because of the selection of the wrong inlet valves, the water temperature should mount above the values of
°C XX , then the machine will automatically inject cold water through the inlet valve i2
(on HF-WE-WE/4) or  i7  (on HFP machines) in order to protect the linen.
The next step will depend on the function selected during the  preprogramming .
- With  SoAP  (liquid soap injection): transfer to  XX. SE-L .
- Without  SoAP  (liquid soap injection): transfer to  SoAP  (or  no SoAP ).