27
Programming mode 4
If during the preprogramming ALArm was selected, then So6 will not be displayed and the display will
immediately move on to XX. SE-L.
Press  E .
XX. SE-L = Select level (of water)
Press " E ".
L XX = Level (of water)
Put in the level of water (by trial and error) with " X,X " and press " E ".
The next step depends on the selection made during "preprogramming".
- With " no LECo " (without level control): transition to " Add " (or " no Add ").
- With " LECo " (with level control): transition to " LECo " (or " no LECo ").
When " 0° " has been put in at " XX. tEMP ", the level can be chosen between 0 and 50.
Overflow (Very dirty linen).
- Put in " 0 °C " (or in °F) at " XX. tEMP ".
- Then select " no HECo ", and choose level " 00 " when " L XX " appears.
The machine will now continuously take water and drain it via the overflow during the entire wash time.
LECo = Level control
If no level control is desired, select " no LECo " and press " E ".
If level control is desired, select " LECo " and press " E ".
LS XX = Level stop
Put in the water level with " X,X " at which the processor must stop (this is automatically limited by the level
chosen in " L XX ").
The microprocessor will proceed as soon as this water level is reached, and the bath will be filled up to the level
chosen in " L XX ". Then press " E ".
å

Related product manuals