29
Programming mode 4
The next step depends on the selection made during "preprogramming".
- With " no Add " (without auxiliary program): transition to " SPin " (or " no SPin ").
- With " Add " (with auxiliary program): transition to " Add " (or " no Add ").
Add = Additional program (Program extension)
If no program extension is desired, select  no Add  and press  E  to confirm (transfer to  SPin ).
If a program extension is desired, select  Add  and press  E  to confirm.
Now select the desired program extensions using NO : Cool , StoP , STOP.tiME , SoAH,
SoAH.tiME  or again  no Add  and confirm the selection by pressing  E .
XX. Cool = Cool-down
CDu XX = Highest cool-down temperature
Select the temperature (between 30 and 85) using  X,X  and press  E  to confirm.
CDn XX = Lowest cool-down temperature
Select the temperature (between 30 and 85 and automatically limited to the value selected under
CDu XX ) using  X,X  and press  E  to confirm.
StoP = Stop
Once in operating mode, the program will stop here, giving the opportunity to e.g. add additional soap or
bleach manually. The water will remain in the tub. See Operating mode: Programmed stop. The stop time
can be programmed up to 999 minutes. Once this stop time has passed, the program will resume
automatically.
StoP.XXX
Select the stop time with  X,X,X  (between 0 and 999 minutes) and confirm by pressing  E .
If  0 was selected, the program will stop indefinitely until the START button is pressed again.
ALArm.XXX
At the beginning of this stop time, the alarm signal can be activated.
Select the duration of the alarm signal using  X,X,X (between 0 and 250 seconds).
This option is only displayed if  ALArm  was selected during the preprogramming.
If " 999 " was selected, the signal will activated during the complete stop time.
SoAH = Soak (soak cycle)
Once in operating mode, the program will stop here, The water level will be increased to  25  and the
machine will execute one left-right movement once every 3 minutes. The temperature will remain constant.
See Operating mode: Soaking. The soak time can be programmed up to 999 minutes. Once this soak time
has passed, the program will resume automatically.
SoAH.XXX
Select the soak time with  X,X,X  (between 0 and 999 minutes) and confirm by pressing  E .
If  0 was selected, the program will stop indefinitely until the START button is pressed again.
ALArm.XXX
At the beginning of this soak time, the alarm signal can be activated.
Select the duration of the alarm signal using  X,X,X  (between 0 and 250 seconds).
This option is only displayed if  ALArm  was selected during the preprogramming.
If " 999 " was selected, the signal will activated during the complete soak time.