31
Programming mode 4
SPin = Spin
If spin is desired, select " SPin " and press " E ".
If no spin is desired, select " no SPin " and press " E ". (Transition to " d0 ", " d1 ", or " d2 ")
SPI- X = Duration of low spin
Put in the duration of the low spin (1 to 9 minutes) with " X " and press " E ".
The next step depends on the selection made during "preprogramming".
- With " no FC " (no frequency controlled motor): transition to " d1 ".
- With " FC " (frequency controlled motor): transition to " LS. XXXX ".
LS. XXXX = Low spin
Put in the speed of low spin (250 to 500 rpm) with " X,X,X,X "and press " E ".
On machines with a drum diameter larger than 850 mm, the high spin speed will be limited to 400 RPM.
d1 = Drain 1 (Drain valve 1)
Select " d1 " or " d2 " with " NO " and confirm with " E ".
d2 = Drain 2 (Drain valve 2)
SP2- X = Duration high spin
Put in the duration of high spin (maximum 15 minutes) with " X " and press " E ". (If no high spin is desired,
put in " 0 ")
The next step depends on the selection made during "preprogramming".
- With " no FC " (frequency controlled motor): transition to " XX. dEti ".
- With " FC " (frequency controlled motor): transition to " HS. XXXX ".
HS. XXXX = High spin (high spin speed)
Select the high spin speed RPM using X,X,X,X (maximally double the low spin speed) and press E to
confirm.
On machines with a drum diameter larger than 850 mm, the high spin speed will be limited to 800 RPM.
XX. dEti = Delay time
Press " E ".
td XXX = Delay time
Put in time with " X,X,X " and press " E ".
Required time: 30 to 180 seconds after spin 1
60 to 180 seconds after spin 2