33
Programming mode 4
d1 = Drain 1
Select " d0 ", " d1 " or " d2 " with " NO " and confirm with " E ".
d2 = Drain 2
d0 = Drain 0 (no drain)
Press " E " to select no drain. (Transition to the last program segment)
dt XXX = Drain time
Select the drain time using X,X,X (maximally 180 seconds) and press E to confirm. Now select between
following functions using  NO  the movement of the drum during draining of the water:  WASh ,  diSt
,  JoLt  and  DrAin . Press  E  to confirm.
WASh = Wash action during drain
diSt = Distribution (distribution speed) (not for machines type WE (no HF))
Distribution of washload during drain
Jolt = Short spin (10 seconds low spin after distribution)
Introduce for this purpose minimum 60 seconds with " Drain ".
Drain=Drain no action
Drain of water without action of drum.
Confirm selection with " E ".
t= XXXX = Time
This is the duration of the program segment.
Press " E ".