What to do if IRadimed Medical Equipment keys won't function?
- KKenneth ChandlerSep 8, 2025
If the keys on your IRadimed Medical Equipment won't function: * Ensure the key is pressed firmly. Repeat the key press, pushing in firmly.
What to do if IRadimed Medical Equipment keys won't function?
If the keys on your IRadimed Medical Equipment won't function: * Ensure the key is pressed firmly. Repeat the key press, pushing in firmly.
Why is IRadimed Medical Equipment battery hard to remove from Pump?
The battery might be hard to remove from the IRadimed Medical Equipment pump due to battery cell failure caused by over-discharge or individual cell failure. Remove or replace the battery in the pump, using appropriate tools as needed.
How to fix IRadimed Medical Equipment pump clock if it is not correct?
If the IRadimed Medical Equipment pump clock is not correct, it may be due to: * The clock not being properly adjusted to local time after receipt. Adjust the clock time as described in the service manual. * Summer/Winter time change. Adjust clock as described in service manual.
What to do if you can't hear the audible alarm on IRadimed Medical Equipment?
If you cannot hear the audible alarm on your IRadimed Medical Equipment, consider the following: * The Occlusion Pressure limits might not be set properly. Adjust the limits to a clinically appropriate level. * The alarm volume might be set too low for the use environment. Adjust the alarm volume for the intended use environment.
What to do if IRadimed Medical Equipment pump settings are restored to default?
If the IRadimed Medical Equipment pump settings are being restored to default, consider these potential causes: * The pump was turned off for longer than one (1) hour between uses. Train appropriate personnel that turning off the pump for more than one (1) hour resets pump settings. * Pump settings changed accidentally. Double check key sequence for feature chosen for correct key sequence. Was “New Patient” chosen?
What to do if Remote Display will not communicate with selected IRadimed Medical Equipment pump?
If the Remote Display will not communicate with the selected IRadimed Medical Equipment pump: * The pump may not be within range. Reposition the pump to establish communication. Verify the pump is within 90 ft (30 m) of the Remote Display. * The pump may not be operational. Verify the pump power is on and the radio antenna is securely attached to both the Pump and Remote Display. * The Pump and Remote Display may not be set at the same channel. Verify in the Set Comm Channel menu option that both the Pump and Remote Display are set to the same comm channel. If not, change the Remote Display to the Pump’s comm channel. * Local radio interference may prevent communication. Select alternate comm channels for both the Pump and Remote Display.
Covers safety instructions, MRI environment use, and patient care.
Specific warnings and precautions related to the pump's operation.
Explains how to operate the system using control keys.
Details the function of each control key on the front panel.
Describes various configurations for starting an infusion.
Calculating pump parameters for dose delivery.
Using a drug library for dose rate calculations.
Using programmed infusion protocols with limits.
Accesses features like Dose Rate Calculation and Alarm Volume.
Steps to prepare the pump for operation.
Verifying pump functionality after setup.
Connecting and setting up the remote display.
Detailed procedures for priming various I.V. sets.
Procedures for inserting and removing I.V. sets from the pump.
Initial setup for infusions, including Rate and VTBI.
Entering flow rate and VTBI for a new infusion.
How to stop or pause an active infusion.
Setting up simultaneous infusions on both channels.
Setting up sequential infusions on one channel.
Steps to set up a secondary infusion.
Entering parameters for a secondary infusion.
How to program and deliver bolus infusions.
Steps to set up and initiate a bolus dose.
Accessing advanced features like Dose Rate Calculation.
Calculating infusion rates based on dose parameters.
Using the calculator with a pre-programmed drug library.
Setting up custom drug protocols.
Configuring pressure limits for occlusion detection.
How the pump detects and responds to air bubbles.
Overview of alarm types and system responses.
Steps to take when an alarm occurs.
Overview of the smart battery pack and its monitoring.
Specific safety precautions for the battery pack.
Overview of the integrated pulse oximeter.
Critical safety warnings for pulse oximeter use.
Precautions for operating the pulse oximeter in an MR environment.
Step-by-step guide for applying the SpO2 sensor.
Information on SpO2 alarms and alerts.
Alarms requiring immediate patient attention.
How to adjust alarm settings.
Common SpO2 problems and their solutions.
Introduction to the DERS option.
Overview of DERS features and benefits.
Instructions for DERS installation and management.
Explains DERS alerts and prompts.
Detailed table of DERS messages and actions.
Step-by-step guide for setting up a primary infusion with DERS.
Detailed steps for primary DERS infusion setup.
How to adjust dose or VTBI during a DERS infusion.
Steps for setting up a bolus dose with DERS.
Setting up dual channel infusions with DERS.
Performing dual channel bolus delivery with DERS.
Solutions for issues with the pump not powering on.
Troubleshooting steps for lack of fluid flow.
Solutions for the pump failing to start.
Troubleshooting fluid leaks from the IV set.
Solutions for the unit not working on battery power.
Troubleshooting short battery life.
Addressing issues with inaccurate fluid delivery.
Identifying causes for premature infusion stoppage.
Troubleshooting causes for infusion stoppage.
Procedure to update the pump's software.
Steps to update the pump software.
Updating software with a remote display.
Instructions for adding the DERS library card.