3860+3860+
OPERATION MANUALOPERATION MANUAL
MRidium
MRI INFUSION/MONITOR SYSTEM
TM
REF 1138REF 1138
IRADIMEDIRADIMED
CORPORCORPORATIONTION

Table of Contents

Other manuals for IRadimed MRIDIUM 3860+

Questions and Answers

  • J
    Joseph CarrilloSep 8, 2025
    What to do if IRadimed Medical Equipment keys won't function?
    • K
      Kenneth ChandlerSep 8, 2025
      If the keys on your IRadimed Medical Equipment won't function: * Ensure the key is pressed firmly. Repeat the key press, pushing in firmly.
  • J
    Jason PrattSep 9, 2025
    Why is IRadimed Medical Equipment battery hard to remove from Pump?
    • R
      ryandylanSep 9, 2025
      The battery might be hard to remove from the IRadimed Medical Equipment pump due to battery cell failure caused by over-discharge or individual cell failure. Remove or replace the battery in the pump, using appropriate tools as needed.
  • T
    Taylor NicholsSep 12, 2025
    How to fix IRadimed Medical Equipment pump clock if it is not correct?
    • N
      Nancy BeardSep 12, 2025
      If the IRadimed Medical Equipment pump clock is not correct, it may be due to: * The clock not being properly adjusted to local time after receipt. Adjust the clock time as described in the service manual. * Summer/Winter time change. Adjust clock as described in service manual.
  • J
    Jesse DavisSep 13, 2025
    What to do if you can't hear the audible alarm on IRadimed Medical Equipment?
    • T
      Travis MoralesSep 13, 2025
      If you cannot hear the audible alarm on your IRadimed Medical Equipment, consider the following: * The Occlusion Pressure limits might not be set properly. Adjust the limits to a clinically appropriate level. * The alarm volume might be set too low for the use environment. Adjust the alarm volume for the intended use environment.
  • L
    Lauren HernandezSep 15, 2025
    What to do if IRadimed Medical Equipment pump settings are restored to default?
    • T
      Tammy WhitneySep 15, 2025
      If the IRadimed Medical Equipment pump settings are being restored to default, consider these potential causes: * The pump was turned off for longer than one (1) hour between uses. Train appropriate personnel that turning off the pump for more than one (1) hour resets pump settings. * Pump settings changed accidentally. Double check key sequence for feature chosen for correct key sequence. Was “New Patient” chosen?
  • A
    Andrew MitchellSep 18, 2025
    What to do if Remote Display will not communicate with selected IRadimed Medical Equipment pump?
    • O
      ooconnorSep 18, 2025
      If the Remote Display will not communicate with the selected IRadimed Medical Equipment pump: * The pump may not be within range. Reposition the pump to establish communication. Verify the pump is within 90 ft (30 m) of the Remote Display. * The pump may not be operational. Verify the pump power is on and the radio antenna is securely attached to both the Pump and Remote Display. * The Pump and Remote Display may not be set at the same channel. Verify in the Set Comm Channel menu option that both the Pump and Remote Display are set to the same comm channel. If not, change the Remote Display to the Pump’s comm channel. * Local radio interference may prevent communication. Select alternate comm channels for both the Pump and Remote Display.

Summary

General Information

Warnings and Precautions

General Warnings and Precautions

Covers safety instructions, MRI environment use, and patient care.

Pump Related Warnings;Precautions

Specific warnings and precautions related to the pump's operation.

SECTION 1 INTRODUCTION

1.2 Controls

Explains how to operate the system using control keys.

1.2.1 Front Panel Control Keys

Details the function of each control key on the front panel.

1.3 Pump Preparation for Use

Describes various configurations for starting an infusion.

Dose Rate Calculator

Calculating pump parameters for dose delivery.

Dose Rate Calculator with Drug Library

Using a drug library for dose rate calculations.

Dose Error Reduction System (DERS) Library (optional)

Using programmed infusion protocols with limits.

1.4 Display

1.4.6 Special Features Setup Menu

Accesses features like Dose Rate Calculation and Alarm Volume.

1.5 User Interface

1.6 System Self Test

1.7 Maintenance and Operator Verification

1.8 Cleaning Instructions

SECTION 2 INSTALLATION

2.5 Preparing the Pump for Use

Steps to prepare the pump for operation.

2.7 Operational Checkout of the Pump

Verifying pump functionality after setup.

2.9 Remote Display Installation

Connecting and setting up the remote display.

SECTION 3 I.V. SET PREPARATION FOR USE

3.2 I.V. Set Priming

Detailed procedures for priming various I.V. sets.

3.3 I.V. Set Insertion and Removal

Procedures for inserting and removing I.V. sets from the pump.

SECTION 4 CONFIGURING THE PUMP FOR USE

4.0 Primary Configuration

Initial setup for infusions, including Rate and VTBI.

Programming a Basic Infusion

Entering flow rate and VTBI for a new infusion.

Canceling;Pausing an Infusion

How to stop or pause an active infusion.

4.1 Dual Channel Infusion

Setting up simultaneous infusions on both channels.

4.2 Secondary (“Piggyback”) Infusion Configuration

Setting up sequential infusions on one channel.

Secondary Infusion Setup

Steps to set up a secondary infusion.

Programming a Secondary Infusion

Entering parameters for a secondary infusion.

4.3 Bolus Delivery

How to program and deliver bolus infusions.

Bolus Setup and Start

Steps to set up and initiate a bolus dose.

4.5 Special Features Menu

Accessing advanced features like Dose Rate Calculation.

4.5.1 Dose Rate Calculation

Calculating infusion rates based on dose parameters.

Dose Rate Calculator with Drug Library

Using the calculator with a pre-programmed drug library.

4.5.4 Occlusion Limits

Configuring pressure limits for occlusion detection.

4.6 Air Bubble Detection and Reset

How the pump detects and responds to air bubbles.

SECTION 5 ALARMS

5.0 Alarms

Overview of alarm types and system responses.

Responding to an Alarm

Steps to take when an alarm occurs.

SECTION 6 BATTERY OPERATION

6.0 Battery Operation

Overview of the smart battery pack and its monitoring.

6.11 Battery Pack Related Precautions

Specific safety precautions for the battery pack.

SECTION 7 PULSE OXIMETER

7.0 Introduction, Pulse Oximeter, 3860+

Overview of the integrated pulse oximeter.

7.0.1 User Warnings and Precautions

Critical safety warnings for pulse oximeter use.

7.4 Operating the 3860+ Pulse Oximeter

Precautions for operating the pulse oximeter in an MR environment.

Applying the Model 1170 Fiberoptic SpO2 Sensor

Step-by-step guide for applying the SpO2 sensor.

7.6 SpO2 Alarms and Alerts

Information on SpO2 alarms and alerts.

Patient and Equipment-Related Alarms

Alarms requiring immediate patient attention.

7.8 SpO2 Troubleshooting

Common SpO2 problems and their solutions.

SECTION 8 DOSE ERROR REDUCTION SYSTEM(DERS)

8.0 Dose Error Reduction System

Introduction to the DERS option.

8.1 Introduction

Overview of DERS features and benefits.

DERS Installation, Removal, Programming or Editing

Instructions for DERS installation and management.

8.4 DERS RELATED ALERT AND USER PROMPT MESSAGES

Explains DERS alerts and prompts.

ALERT; PROMPT - MESSAGES, TYPE, CAUSE AND RESOLUTION

Detailed table of DERS messages and actions.

8.6 SETTING UP A DERS PRIMARY INFUSION

Step-by-step guide for setting up a primary infusion with DERS.

SETTING UP A DERS PRIMARY INFUSION

Detailed steps for primary DERS infusion setup.

Adjusting a Dose or the VTBI During an Infusion

How to adjust dose or VTBI during a DERS infusion.

SETTING UP A DERS BOLUS

Steps for setting up a bolus dose with DERS.

DUAL CHANNEL DERS INFUSION

Setting up dual channel infusions with DERS.

DUAL CHANNEL BOLUS DELIVERY

Performing dual channel bolus delivery with DERS.

APPENDIX F TROUBLESHOOTING

Pump won’t turn on

Solutions for issues with the pump not powering on.

No Fluid Flow

Troubleshooting steps for lack of fluid flow.

Pump wont start

Solutions for the pump failing to start.

Fluid Leaking from Administration Set

Troubleshooting fluid leaks from the IV set.

Unit wont operate on battery

Solutions for the unit not working on battery power.

Battery operation is too short

Troubleshooting short battery life.

Fluid delivery seems inaccurate

Addressing issues with inaccurate fluid delivery.

Infusion prematurely stopped

Identifying causes for premature infusion stoppage.

Infusion stops

Troubleshooting causes for infusion stoppage.

APPENDIX G 1119 I.V. POLE ASSEMBLIES AND PARTS DESCRIPTIONS

1119 Assembly Instruction Rev. C 010308

APPENDIX I 1145 Dose Error Reduction System

B. To update the current IV Pump Software:

Steps to update the pump software.

D. To add the DERS Library programming card:

Instructions for adding the DERS library card.

IRadimed MRIDIUM 3860+ Specifications