EasyManua.ls Logo

ISDT Q6 PLUS - Troubleshoot

ISDT Q6 PLUS
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Uspvcmftippu
Error in power on self-testing: the charger can automatically carry out a self-testing when
connected to a power supply. A self-testing error warning sound should be heard when the
charger is connected to the battery; power on after removing the battery for 5 minutes.
Error for abnormal battery connection: pull out and plug in the battery again to ensure all
connections are reliably contacted; if the error reminder continues, please check whether the
metal parts on the battery interface are oxidized or burned resulting in unreliable connection.
Error for unstable power voltage: check whether the battery socket is reliably connected, and
whether the power of electric supply can match the input requirement of the charger. If the
power is smaller than 160 W, please adjust the max input power to match the power of
electric supply in the system fault menu of the charger.

Related product manuals