Do you have a question about the Isotherm Classic Compact 2009 and is the answer not in the manual?
Examine contents for shipping damage and notify carrier if necessary.
Ensure electrical circuits are off before working on the system and follow ABYC standards.
List of tools and materials needed for installation, including drill, wire tools, and screws.
Proper installation and box construction are key for efficient operation and low power consumption.
Plan tubing/wire runs, avoid dirt on couplings, ensure ventilation, use dedicated circuit breaker.
Position compressor for optimal heat transfer with adequate inlet/outlet vents.
Ensure a good electrical connection with minimal voltage loss for efficient operation.
Use a regulated battery charger of at least 5 amps capacity connected to the battery.
Connect directly to the battery or main switch using correct cable dimensions.
Mount in a well-ventilated location, within 6 feet of evaporator, horizontally.
Mount horizontally or vertically near the box top, consider tubing routing and avoid sharp bends.
Install in a dry area, ensure capillary tube is long enough, connect wiring to electronic unit.
Connect couplings carefully, keep them clean, and avoid twisting tubing during tightening.
Turn on circuit, compressor should start within 30s; adjust thermostat for desired temperature.
Compressor shuts off on overload or low/high battery voltage; monitors input voltage.
Examine contents for shipping damage and notify carrier if necessary.
Ensure electrical circuits are off before working on the system and follow ABYC standards.
List of tools and materials needed for installation, including drill, wire tools, and screws.
Proper installation and box construction are key for efficient operation and low power consumption.
Plan tubing/wire runs, avoid dirt on couplings, ensure ventilation, use dedicated circuit breaker.
Position compressor for optimal heat transfer with adequate inlet/outlet vents.
Ensure a good electrical connection with minimal voltage loss for efficient operation.
Use a regulated battery charger of at least 5 amps capacity connected to the battery.
Connect directly to the battery or main switch using correct cable dimensions.
Mount in a well-ventilated location, within 6 feet of evaporator, horizontally.
Mount horizontally or vertically near the box top, consider tubing routing and avoid sharp bends.
Install in a dry area, ensure capillary tube is long enough, connect wiring to electronic unit.
Connect couplings carefully, keep them clean, and avoid twisting tubing during tightening.
Turn on circuit, compressor should start within 30s; adjust thermostat for desired temperature.
Compressor shuts off on overload or low/high battery voltage; monitors input voltage.
| Brand | Isotherm |
|---|---|
| Model | Classic Compact 2009 |
| Category | Refrigerator |
| Language | English |