iSpring Water Systems Page 6
Preparation
Determine the location for installation of the RO system.
Determine the location for installation of the RO faucet.
You may use the existing predrilled hole on the sink. Make sure the
washer is big enough to cover the hole.
If you drill a new hole on the countertop or sink, make sure that drilling
the hole will not damage any pipe or wiring underneath the
countertop or sink.
Determine the location for the water storage tank.
The pressure storage tank can stand up straight or lie down at the
desired location.
The maximum distance between the storage tank and the RO faucet
is 15 feet. The system will produce a faster flow at the RO faucet if
you use the shortest tubing possible from the tank to the RO faucet.
Before Installation: Shut Off the Water Supply
Locate both the cold and hot water supply shut-off valves underneath
the sink. Turn OFF both the cold and hot water shut-off valves.
Only hook up the water supply to the RO system from the COLD water
feed line. CAUTION: Hot water will permanently damage the RO
system.
If no shut-off valve is located under the sink, turn off the main water
supply at the entry to the house.
CAUTION
DO NOT USE WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF
UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE
OR AFTER THE SYSTEM.