DCM600 to 1800 - Instruction Manual
As with traditional Dwyer products, the Dwyer DCT1000 was designed so that it is easy to use, thus allowing
for a quick and easy start up for your dust control applications. The contents inside this installation and
operating manual will guide you through the features of the DCT1000 and how they can be applied to get
the most out of your dust control requirements.
Thank you for purchasing the sequential
controller DCT1000. You have selected a
model of its kind in the field of controller
that will provide years of operation with
high reliability.
Sequential Controller DCT1000 has been
designed for use with pulse jet type dust
collectors for cleaning applications on
demand or continuously.
The continuous cleaning applications
require no external inputs and can be
used depending on demand through the
use of the functionality of cycle time.
For on-demand applications, the pressure
modules (DCP100A/200A) optional can be
used to enjoy all the features of DCT1000,
or switch to external pressure (eg Dwyer
Photohelic ®) can be used to control high
/ low limit.
SPECIFICATIONS
• Output Channels: 6, 10, & 22 channels. Expandable to 255
• channels using DCT1122 & DCT1110 channel expander boards.
• Power Requirements: 85 to 270 V AC, 50 or 60 Hz.
• Solenoid Supply: 3 A maximum per channel.
• Fuse: 3 A @ 250 V AC. Low voltage control circuitry is isolated from
• the line voltage for system safety.
• Temperature Limits: -40 to 140°F (-40 to 60°C).
• Storage Temperature Limits: -40 to 176°F (-40 to 80°C).
• On Time: 10 millisec. to 600 millisec. , 10 millisec. by steps.
• On Time Accuracy: ±10 millisec. .
• O Time: 1 second to 255 seconds, 1 second steps.
• O Time Accuracy: ±1% of the value or ±50 millisec. , whichever is greater.
• Weight: 1 lb 3.0 oz (538.6 g).
• Agency Approvals: UL, cUL.
SPECIFICATIONS - INSTALLATION AND OPERATING
SEQUENTIAL CONTROLLER DCT1000 SPECS