MAINTENANCE
POINTS FOR
MAINTENANCE
DAILY
WEEKLY
QUARTERLY
SIX-MONTHLY
ANNUAL
RECOMMENDATIONS
Check the water temperature in
the generator.
Check the temperature with the temperature and
pressure gauge on the generator's control panel.
Check the generator's outlet
temperature.
Check the temperature with the thermometer on
the mixing valve.
METERING PRODUCT
Chemical products.
x
Check the levels of chemical products.
Dosing pumps
x
Check that the dosing pumps are working properly.
WATER SOFTENER
Salt level
x
Make sure the level of salt in the brine tank is
above the water level.
INFORMATION
» For a list of maintenance points, see section “Elements installed”.
» ISTOBAL recommends the use of original chemical products.
MAINTENANCE TABLE FOR TECHNICAL ENGINEERS
POINTS FOR
MAINTENANCE
HOURS
RECOMMENDATIONS
Oil change (1st change) 50 Replace the oil in the pump’s crankcase. The oil type to be used is ISO68.
Subsequent oil changes. 500 Replace the oil in the pump’s crankcase. The oil type to be used is ISO68.
Check valves, seats and
springs.
2000
Remove the caps from the cylinder head and check the state of the valves
and seats and that there are no impurities in them.
Check high pressure
gaskets.
3000 Check condition of high pressure gaskets.
Check the oil retainers 5000 Check condition of oil retainers.
Boiler and burner service.
The boiler, burner and safety devices should be cleaned and serviced
annually. The combustion settings should also be checked at the same
time.