Loading...
PROTect Subsystem
Copyright© Itech Electronic Co., Ltd. 58
Returns
<NRf>
PROTect:RMS:CURRent:TIME
This command is used to set the delay time of OCP.
Syntax
PROTect:RMS:CURRent:TIME <NR1>
Arguments
<NR1> 0 ~ 9999 ms
Query Syntax
PROTect:RMS:CURRent:TIME?
Returns
<NR1>
PROTect:RMS:CURRent:MAX[:LEVel]
This command is used to set the maximum value of the OCPrms setting value.
Syntax
PROTect:RMS:CURRent:MAX[:LEVel] <NRf>
Arguments
<NRf>
Query Syntax
PROTect:RMS:CURRent:MAX[:LEVel]?
Returns
<NRf>
PROTect:RMS:CURRent:MIN[:LEVel]
This command is used to set the minimum value of the OCPrms setting value.