EasyManuals Logo

ITech IT-M7723 Programming Guide

ITech IT-M7723
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
3-phase/series commands
Copyright© Itech Electronic Co., Ltd. 103
MEASure[:SCALar]:FREQuency?
This command reads the frequency.
Syntax
MEASure[:SCALar]:FREQuency?
Arguments
None
Returns
< NRf >
MEASure[:SCALar]:CURRent:PEAK?
This command reads the positive peak current.
Syntax
MEASure[:SCALar]:CURRent:PEAK? <A|B|C|ALL>
Arguments
<A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>
MEASure[:SCALar]:VOLTage:PEAK?
This command reads the positive peak voltage.
Syntax
MEASure[:SCALar]:VOLTage:PEAK? <A|B|C|ALL>
Arguments
<A|B|C|ALL>
Returns
<NRf|NRf|NRf|NRf,NRf,NRf>

Table of Contents

Other manuals for ITech IT-M7723

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M7723 and is the answer not in the manual?

ITech IT-M7723 Specifications

General IconGeneral
BrandITech
ModelIT-M7723
CategoryPortable Generator
LanguageEnglish

Related product manuals