Measurement Commands 
  Copyright © Itech Electronic Co., Ltd.  27 
Chapter9 Measurement Commands 
MEASure:CURRent? 
This order is used to measure and return output current value. 
Order syntax 
MEASure[:SCALar]:CURRent[:DC]? 
Return parameters 
<NR2> 
FETCh:CURRent? 
This order is used to read the latest current to be processed from sampling 
buffer. When you send this order, then our unit will communicate with PC, and 
sending the current data to PC. This  order will not  affect our  unit’s setting or 
trigger the measurement operation. It only needs the nearest reading it can get. 
The returned readings will keep the old before it get a new data. 
Order syntax 
FETCh:CURRent[:DC]? 
Return parameters 
<NR2> 
MEASure[:VOLTage]? 
This order can inquire the current output voltage value. 
Order syntax 
MEASure[:SCALar][:VOLTage][:DC]? 
Return parameters 
<NR2> 
FETCh[:VOLTage]? 
This  order  is  used  to  read  the  latest  preprocessed  voltages  from  sampling 
buffer. 
Order syntax 
FETCh[:VOLTage][:DC]? 
Return parameters 
<NR2>