List Commands
Copyright © Itech Electronic Co., Ltd. 29
Chapter10 List Commands
LIST:FUNCtion
This order is used to select the state of list mode.
Order syntax
[SOURce:]LIST:FUNCtion <0|1>
Query syntax
[SOURce:]LIST:FUNCtion?
Return parameters
0|1
LIST:VOLTage
This order is used to set the steps of list file and voltage of current step.
Order syntax
[SOURce:]LIST:VOLTage <NRf>
Parameters
MIN to MAX
Unit
V
Example
LIST:VOLT 1, 3V //set the first step’s voltage to be 3V.
Query syntax
LIST:VOLTage?
Example
LIST:VOLT? 1 //inquire the first step’s voltage.
Return parameters
<NR2>
LIST:CURRent
This order is used to set the steps of list file and current value of current step.
Order syntax
[SOURce:]LIST:CURRent <NRf>